ZKU15 Voltage Current Testing Meter LCD Digital Display Multifunctional Volt Ammeter

9,84 €
+ 9,83 € Envio

ZKU15 Voltage Current Testing Meter LCD Digital Display Multifunctional Volt Ammeter

  • Marca: Unbranded
Vendido por:

ZKU15 Voltage Current Testing Meter LCD Digital Display Multifunctional Volt Ammeter

  • Marca: Unbranded

9,84 €

Economize 4,43 € (31%)

PVP

14,27 €
Em stock
+ 9,83 € Envio
Vendido por:

9,84 €

Economize 4,43 € (31%)

PVP

14,27 €
Em stock
+ 9,83 € Envio

Aceitamos as seguintes formas de pagamento

Descrição

Condition: 100% Brand New <br>Item Type: Multifunction Volt-Ammeter <br>Material: Plastic Housing <br> <br>Product Size: Approx. 79 x 42 x 26mm/3.1 x 1.7 x 1in <br>ModelZK-U15 <br>Input VoltageDC 5V-38V(With Anti-Reverse Connection) <br>Input Current0.03A-5.00A <br>Operating Current<=30mA <br>Voltage Accuracy(±1%+1 Word) <br>Accuracy of Current(±1%+1 Word) <br>Working Environment Temperature-15℃-50℃ <br>LVP Threshold of Undervoltage Protection4.8V by Default (Adjustable between 4.8V-38V) <br>OVP Threshold for Overvoltage ProtectionDefault 38.0V(Adjustable between 4.8V-38.0V) <br>OCP Threshold for Overcurrent ProtectionDefault 5.5A (Adjustable between 0.5A-5.5A) <br>OTP Threshold of Overtemperature Protection80℃(Adjustable between 40℃-80℃) <br>OCP Threshold for Overcurrent ProtectionDefault 5.5A (Adjustable between 0.5A-5.5A) <br>OPP Threshold of Overpower ProtectionDefault 200W(Adjustable between 1W-200W) <br> <br> <br>Detailed Product Function: <br>1. LCD screen display <br>In the normal mode, the LCD screen displays the input voltage and working temperature in the upper; the lower displays the real-time current, power, capacity and discharge time. In the protection mode, the LCD screen displays the protection codes. <br>In the setting mode, the LCD screen displays each setting parameter codes and parameter threshold. <br>2. Sound and light alarm <br>When the voltage and current meter output is turned on, the RUN indicator light is always on and the buzzer does not sound; when it is turned off, the RUN indicator light does not light, and the buzzer does not sound. After entering the protection mode, the buzzer will alarm and the RUN indicator will flash. <br>3. Automatic statistics of charge and discharge capacity and time. As long as the output is turned on (the RUN indicator is always on), the statistics will be started, and the output will be turned off (the RUN indicator is not on), and the statistics will be stopped. In the interface, long press the button-the corresponding data can be cleared. Start <br>Before statistics, please clear the statistics data to 0. The maximum discharge capacity (OAH) and maximum discharge time (OHP) can be set on or off in the setting mode (default off). After being turned on, the threshold value can be set. If the threshold value is exceeded, the output will be automatically turned off and the buzzer will alarm to achieve no Charging and discharging the battery on duty. <br>4. By setting appropriate over-voltage protection threshold and under-voltage protection threshold, battery overcharge and overdischarge control can be achieved. For detailed operation, please refer to the product application example. <br>5. Complete software and hardware protection mechanism, and the software protection threshold can be adjusted. After software protection, the output is turned off. <br> <br>Hardware Protection: <br>The input port of the module has anti-reverse connection protection, and the reverse connection will not burn. <br> <br>Software Protection: <br>OVP overvoltage protection (default 38V, can be set by yourself, after overvoltage protection, the RUN indicator flashes, and the LCD interface displays OVP. During battery charging, setting a proper threshold can effectively prevent battery overcharging); <br>OCP overcurrent protection (default 5.5A, can be set by yourself, after overcurrent protection, the RUN indicator flashes, and the LCD displays OCP); <br>OPP over power protection (default 200W, can be set by yourself, after over power protection, RUN indicator flashes, LCD shows OPP); <br> <br> <br>Steps for Usage: <br>1. First connect the battery and load, and check whether the wiring is correct. <br>2. The voltage and current meter enters the normal interface. If it is not in the normal interface, short press the ON button to return to the normal inte
  • Marca: Unbranded
  • Categoria: Higrómetro
  • Peso: 0.5
  • Comprimento: 10
  • Altura: 5
  • Largura: 5
  • Identificação da Fruugo: 348696136-761106664
  • EAN: 4853222497129

Informações de segurança do produto

Consulte as informações de segurança do produto específicas para este produto descritas abaixo

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Etiquetas de segurança do produto

CE Mark

Entrega e Devoluções

Enviado dentro de 24 horas

  • STANDARD: 9,83 € - Entrega entre sexta 07 novembro 2025–sexta 14 novembro 2025

Enviamos a partir de China.

Fazemos o nosso melhor para garantir que os produtos que encomendar lhe serão entregues na totalidade e conforme as suas especificações. No entanto, se receber uma encomenda incompleta ou itens diferentes dos que encomendou, ou existir qualquer outra razão pela qual não estiver satisfeito com a sua encomenda, poderá devolver a encomenda ou quaisquer produtos incluídos na mesma, e receber um reembolso total dos itens. Ver a política de devoluções na íntegra

Detalhes de conformidade do produto

Consulte as informações de conformidade específicas para este produto descritas abaixo.

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Fabricante:
As informações seguintes apresentam os dados de contacto do fabricante do produto em causa vendido na Fruugo.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 903, Building B, Nanxian Commercial Plaza, Nanyuan New Village
  • Hongshan Community, Minzhi Subdistrict, Longhua District
  • Longhua
  • Shenzhen
  • China
  • 518500
  • szrhkj21@163.com
  • 15819859068

Pessoa responsável na UE:
As informações seguintes apresentam os dados de contacto da pessoa responsável na UE. A pessoa responsável é o operador económico designado, sedeado na UE, incumbido das obrigações de conformidade relativas ao produto em causa vendido na União Europeia.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736