YB4835VA DC0~100V 20A Dual Display Integrated Voltage Ampere Meter

13,36 €
+ 9,83 € Envio

YB4835VA DC0~100V 20A Dual Display Integrated Voltage Ampere Meter

  • Marca: Unbranded

YB4835VA DC0~100V 20A Dual Display Integrated Voltage Ampere Meter

  • Marca: Unbranded
Preço: 13,36 €
Vendido por:
13,36 €
+ 9,83 € Envio

Em stock

Aceitamos as seguintes formas de pagamento

Descrição

Features: <br> <br>The meter head is a common design, i. e. the ground wire at the measuring end is interlinked with the ground wire at the power supply end (except the isolation meter). <br>The meter head is equipped with voltage calibration potentiometer, current calibration potentiometer, if there is any error, you can calibrate it, because the error is absolute. <br>The voltage meter adopts the design of automatic movement of the decimal point. <br>This meter has strong anti-interference ability and fast display refresh rate. <br>The meter head uses a wide power supply range: DC3.5 ~ 30V (except the isolation meter), the power supply reverse connection will not burn. <br>The meter head is equipped with five wiring, the connection is convenient, it is used to monitor the voltage of the battery, to grasp the voltage state of the battery in time, and to measure the voltage and current of other products. <br> <br>Specification: <br>Voltage Measuring Range 0~99.9V <br>Resolution 0.01V(<10v)/0.1v(10~100V) <br>Ampere Measuring Range 0-9.99-20A <br>Resoluction 0.01A(<10A)/0.1A(>10A) <br>Measurement rate ≥ 500mS/ times <br>Measurement accuracy 1% (± 1 word) <br>Minimum supply voltage +3.5V <br>Maximum supply voltage + 30V <br>Operating temperature -10 ~ + 65 <br>Working humidity 10 ~ 80% (without condensation) <br>Working pressure 80 ~ 106 kPa <br>Sunlight exposure no direct exposure <br> <br> <br>Note: <br>Power supply voltage (non-isolation meter): DC3.5 ~ 30V (wide range), note: maximum input voltage should not exceed 30V, otherwise there is risk of burning <br>The watch head of 20A _ built-in shunt <br>Since a 24V battery may have a floating voltage of more than 30V after it is filled, it is recommended that the "no" supply it directly with 24V batteries <br>In the following cases, it is strongly recommended that: isolation meter (isolation power supply meter) <br>When two or more meters are installed in a device, they cannot be alone, independent, or isolated when power is supplied <br> <br>Connection method: <br>This meter is equipped with five lines, please find professionals strictly according to the following wiring diagram, if any questions, please feel free to contact customer service: <br> <br>Meter head power supply: two-wire socket <br>Fine _ black line: meter head power supply <br>Fine _ red line: power supply to watch head is positive (note, the voltage between fine red and black line cannot exceed 30V) <br> <br>Isolation meter (isolated power supply): <br>The meter head power supply end and the test end are completely insulated and isolated from each other, can share one power source in multiple meters, "no need" is worried about all kinds of interference problems caused by sharing the power supply, suitable for the factory aging test stand, test stand, or other equipment requiring more than one meter head <br>Power supply voltage: DC8-18V <br> <br>Test end: <br>COM: Test Common End <br>V +: Test positive voltage input <br>A +: Test "positive" current input end;Because the meter head adopts the common ground design, that is, the ground wire at the measuring end is connected with the ground wire at the power supply end, so it can only be connected between the negative and the negative power supply of the equipment under test, as shown in the following figure, the connection error will burn, (if only do voltmeter use, it is recommended to connect the yellow line with the black line, Prevent the digital flicker of ammeter caused by external interference) <br>Non-shunt _ connection method: suitable for "below 20A" without external connection.<br>1、The meter head is a common design, i. e. the ground wire at the measuring end is interlinked with the ground wire at the power supply end (except the isolation meter). <br>2、The meter head is equipped with voltage
  • Identificação da Fruugo: 347153595-758652545
  • EAN: 929768610705

Entrega e Devoluções

Enviado dentro de 24 horas

  • STANDARD: 9,83 € - Entrega entre quarta 08 outubro 2025–quarta 15 outubro 2025

Enviamos a partir de China.

Fazemos o nosso melhor para garantir que os produtos que encomendar lhe serão entregues na totalidade e conforme as suas especificações. No entanto, se receber uma encomenda incompleta ou itens diferentes dos que encomendou, ou existir qualquer outra razão pela qual não estiver satisfeito com a sua encomenda, poderá devolver a encomenda ou quaisquer produtos incluídos na mesma, e receber um reembolso total dos itens. Ver a política de devoluções na íntegra

Detalhes de conformidade do produto

Consulte as informações de conformidade específicas para este produto descritas abaixo.

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Fabricante:
As informações seguintes apresentam os dados de contacto do fabricante do produto em causa vendido na Fruugo.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 903, Building B, Nanxian Commercial Plaza, Nanyuan New Village
  • Hongshan Community, Minzhi Subdistrict, Longhua District
  • Longhua
  • Shenzhen
  • China
  • 518500
  • szrhkj21@163.com
  • 15819859068

Pessoa responsável na UE:
As informações seguintes apresentam os dados de contacto da pessoa responsável na UE. A pessoa responsável é o operador económico designado, sedeado na UE, incumbido das obrigações de conformidade relativas ao produto em causa vendido na União Europeia.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736