Rain and Snow Sensor Module Snow Raindrops Detection Sensor 485 Mode Automatic Heating 10‑30V

39,95 €
+ 4,49 € Envio

Rain and Snow Sensor Module Snow Raindrops Detection Sensor 485 Mode Automatic Heating 10‑30V

  • Marca: Unbranded

Rain and Snow Sensor Module Snow Raindrops Detection Sensor 485 Mode Automatic Heating 10‑30V

  • Marca: Unbranded
PVP: 54,00 €
Preço: 39,95 €
Poupa: 14,05 € (26%)
Vendido por:
39,95 €
+ 4,49 € Envio

Em stock

Aceitamos as seguintes formas de pagamento

Descrição

Rain and Snow Sensor Module Snow Raindrops Detection Sensor 485 Mode Automatic Heating 10‑30V Item Type: Rain and Snow Sensor Material: Plastic Weight: Approx. 153g/5.40oz Size: 89x64x38mm/3.50x2.52x1.50in Power Supply: 10-30V DC Normal Working Power:0.4W Storage Environment:-40℃-80℃ Output Signal: 485 Parameter Configuration: Software setting Default Address: 01 Support Function Code: 03, 06 Maximum Heating Temperature: 40℃ Output Relay With Load Capacity: 250VAC 1A, 30VDC 1A Product Model: RS YUX N01 H Product Type: 485 mode, automatic heating Wire Sequence: VCC(brown) GND(black) A(yellow) B(blue) Ambient Temperature For Heating Start: <15°C (default) Maximum Heating Temperature: 40℃(default) Working Power When Heating:2.4W Application: It can be widely used in the qualitative measurement of the presence or absence of rain and snow in the environment, greenhouses, breeding, buildings, buildings, etc. Power: Positive power supply (10-30V DC) (brown), Power negative (black) Output: 485 A(yellow), 485 B(blue) Possible reason that device cannot connect to the PLC or computer: 1) The computer has multiple COM ports, and the selected port is incorrect. 2) The device address is wrong, or there are devices with duplicate addresses (the factory defaults are all 1). 3) The baud rate, check method, data bit, stop bit are wrong. 4) The host polling interval and waiting response time are too short, and both need to be set above 200ms. 5) The 485 bus is disconnected, or the A and B wires are connected reversely. 6) If the number of equipment is too much or the wiring is too long, power supply should be nearby, add a 485 booster, and add a 120Ω terminal resistance. 7) The USB to 485 driver is not installed or damaged. 8) The equipment is damaged. Description of alarm reset delay setting If this value is set to 10S, the device will consider the device to detect rain and snow and output an alarm state if the duration of rain and snow detected exceeds 10S, and if the duration of rain and snow detected is less than 10S, the device will consider it not detected To rain and snow; the same is true when rain and snow return to normal. Default value: 1 second Range: 0-60000 seconds Sensitivity setting description: The sensitivity value is inversely proportional to the actual sensitivity. The larger the set value, the less sensitive the device detection, and the smaller the sensitivity value, the more sensitive the device detection. But it should be noted that if the sensitivity value is too small, it is easy to cause false alarms. It is recommended e the factory default value. Default value: 800 Range: 500-3500 Data frame format definition Using RTU communication protocol, the format is as follows: Initial structure ≥ 4 bytes of time Address code = 1 byte Function code = 1 byte Data area = N bytes Error check = 16-bit CRC code Time to end structure ≥ 4 bytes Address code: the address of the transmitter, which is unique in the communication network (factory default 0x01). Function code: The command function instruction issued by the host, this transmitter only uses function codes 0x03 and 0x06. Data area: The data area is the specific communication data, pay attention to the high byte of the 16bits data first! CRC code: two byte check code.
  • Identificação da Fruugo: 390329828-836311671
  • EAN: 7631310956959

Entrega e Devoluções

Enviado dentro de 24 horas

  • STANDARD: 4,49 € - Entregue por terça 07 outubro 2025

Enviamos a partir de China.

Fazemos o nosso melhor para garantir que os produtos que encomendar lhe serão entregues na totalidade e conforme as suas especificações. No entanto, se receber uma encomenda incompleta ou itens diferentes dos que encomendou, ou existir qualquer outra razão pela qual não estiver satisfeito com a sua encomenda, poderá devolver a encomenda ou quaisquer produtos incluídos na mesma, e receber um reembolso total dos itens. Ver a política de devoluções na íntegra

Detalhes de conformidade do produto

Consulte as informações de conformidade específicas para este produto descritas abaixo.

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Fabricante:
As informações seguintes apresentam os dados de contacto do fabricante do produto em causa vendido na Fruugo.

  • shenzhenshijiangjunfudianzishangwuyouxiangongsi
  • shenzhenshijiangjunfudianzishangwuyouxiangongsi
  • BantianjiedaoxiangjiaotangshequzhonghaogongyechengC2dongwuceng505
  • Longgangqu
  • Shenzhenshi
  • Guangdongsheng
  • China
  • 518000
  • Wallace22578@outlook.com
  • +8613084447403

Pessoa responsável na UE:
As informações seguintes apresentam os dados de contacto da pessoa responsável na UE. A pessoa responsável é o operador económico designado, sedeado na UE, incumbido das obrigações de conformidade relativas ao produto em causa vendido na União Europeia.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659