DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

21,95 €
+ 8,99 € Envio

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

  • Marca: Unbranded
Vendido por:

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

  • Marca: Unbranded

21,95 €

Economize 13,00 € (37%)

PVP

34,95 €
Em stock
+ 8,99 € Envio

Política de Devoluções de 14 Dias

Vendido por:

21,95 €

Economize 13,00 € (37%)

PVP

34,95 €
Em stock
+ 8,99 € Envio

Política de Devoluções de 14 Dias

Métodos de pagamento:

Descrição

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

①. DC Current Detection Module Relay Switch Sensor Digital Display Motor Controller 12V ②. Item Type: DC Current Detection Module ③. Product Model: YYI-2. When the detection current is too large or too small, the control relay switch will control the circuit to be on or off, or give a signal; ④. Detection Accuracy: 0.01A (10mA) ⑤. Error Calibration: With error calibration function, and the display can be turned off for a long time to reduce power consumption; ⑥. Standby Current: About 20mA; ⑦. Relay Output: Can control the on and off of DC lines within 10A; ⑧. Function ⑨. 1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected; ⑩. 2. P-12: When the measured current is greater than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑪. 3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected; ⑫. 4. P-22: When the measured current is greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑬. 5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected; ⑭. 6. P-32: When the measured current is less than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑮. 7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected; ⑯. 8. P-42: When the measured current is between I1 and I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑰. 9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected; ⑱. 10. P-52: When the measured current is less than I1 or greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑲. Setting Instructions: ⑳. 1. Power on to display the measured current; (if the measured current terminal is suspended, the number of digital display is normal); ㉑. 2. The first time K1 is pressed, it takes more than 1 second to be effective to prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function; ㉒. 3. Press K1 for the second time, the screen flashes: 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus; ㉓. 4. Press K1 for the third time, the screen flashes: 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus; ㉔. 5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state; ㉕. 6. In standby mode, long press K2 or K3 to fine tune the measured current error.
  • Identificação da Fruugo: 462328378-973119946

Entrega e Devoluções

Enviado dentro de 3 dias

  • STANDARD: 8,99 € - Entrega entre segunda 09 fevereiro 2026–quarta 18 fevereiro 2026

Enviamos a partir de China.

Fazemos o nosso melhor para garantir que os produtos que encomendar lhe serão entregues na totalidade e conforme as suas especificações. No entanto, se receber uma encomenda incompleta ou itens diferentes dos que encomendou, ou existir qualquer outra razão pela qual não estiver satisfeito com a sua encomenda, poderá devolver a encomenda ou quaisquer produtos incluídos na mesma, e receber um reembolso total dos itens. Ver a política de devoluções na íntegra

Detalhes de conformidade do produto

Consulte as informações de conformidade específicas para este produto descritas abaixo.

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Fabricante:
As informações seguintes apresentam os dados de contacto do fabricante do produto em causa vendido na Fruugo.

  • Guangzhou Qiyi E-Commerce Co., Ltd.
  • LnitOne2
  • 3 Tangdong East Road, Unit 216, G282
  • Tianhe District
  • Guangzhou
  • china
  • 510620
  • qiyihappiness@163.com
  • (+86) 16620020838

Pessoa responsável na UE:
As informações seguintes apresentam os dados de contacto da pessoa responsável na UE. A pessoa responsável é o operador económico designado, sedeado na UE, incumbido das obrigações de conformidade relativas ao produto em causa vendido na União Europeia.

  • Jessie Peng
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt am Main, Hessen,
  • Frankfurt am Main
  • Germany
  • 60486
  • successservice3@gmail.com
  • (+49) 6934873848