5V - 24V Motor Forward / Reverse Controller Timing Delay Time Cycles Relay
Features:
Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.5-25V; Power supply 2, DC 5V
Working current: (Normal Mode) standby current 41mA, working current 83mA; (Energy-Saving mode) Standby current 7mA, working current 44mA.
There are three input control port: forward control(FWD), reverse control(REV), and stop control(STOP).
Two input trigger modes, Low-Pulse trigger mode, Low-Level trigger mode
Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes.
Cycle times: no cycle, 2-99 cycles, always cycle.
Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).
Relay load current, recommended less than 5A.
This is a multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings.
Port:
DC 5.5MM female : Power supply 1, DC 5V power supply.
VIN: Power 2 positive, DC 6.5-25V power supply
GND: Power supply 2 negative
FWD: Forward input control (partial Function-Mode is invalid)
REV: Reverse input control (partial Function-Mode is invalid)
STOP : Stop input control (partial Function-Mode is invalid)
M+: Motor positive
M-: Motor negative
P+: Positive terminal for motor power supply
P-: negative terminal for motor power supply
Specification:
Power supply: DC 6.5-25V, DC 5V
Working current: 83mA
Standby current: 41mA
Relay load current: <5A
Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes
Size: 8*5cm/3.2*2in
Weight: Approx. 51g/1.8oz
Trigger mode:
1 low pulse trigger (falling edge trigger)
2 low level trigger (rising edge trigger)
Timer:
T1: Forward timer
T2: Reverse timer
T3: Stop timer
Time unit : 0.1 second, 1 second, 1 minute
Relay action:
Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing.
Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing..
Motor stop : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.
Factory settings:
Press the "++" and "--" buttons simultaneously for 5 seconds.
Energy-saving mode:
Press and hold the "OK" button for 5 seconds to enter
the "Energy-saving mode". Press and hold the "OK" button again for 5
seconds to exit the "Energy-saving mode". Energy saving mode just turns
off the digital tube and LED indicator, and other functions are normal.
Function mode:
F-01
After power-on, the motor is forward T1 time; then the
motor stops T3 time; then the motor reverse T2 time; so it is repeated
Nx times. When the STOP port is triggered, the motor stops working
immediately. (FWD, REV port is invalid)
F-02
This function is a F-01 variant. F-01 is run directly
after power-on, but F-02 needs to trigger FWD or REV port to run.
F-11(Trigger reversible 1)
Trigger the FWD port, the motor is forward T1 time, and
automatically stops (in order to protect the motor, during the delay
period, trigger the REV port to stop T3 time and then reverse T2 time,
trigger FWD port to re-time T1).
Trigger the REV port, the motor is reverse T2 time, and
automatically stops (in order to protect the motor, during the delay
period, the FWD port is triggered to stop the T3 time and then the T1
time is forward, and the REV port is re-timed T2).
When the STOP port is triggered, the motor stops
immediately, regardless of whether the motor is forward or reverse.
F-12(Trigger reversible 2)
Trigger the FWD port, the motor is forward T1 time and
stops automatically (during the delay period, except for triggering STOP
port, the other ports are invalid).
Trigger the REV port, the motor is reverses T2 time, and
automatically stops (during the delay period, except for triggering
STOP port, the other ports are invalid).
When the STOP port is trigger, the motor stops
immediately, regardless of whether the motor is forward or reverse.
F-21
When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.
When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.
In this mode, the FWD and REV ports cannot be connected
low level at the same tim
-