Cycle Trigger Delay Timer Switch Circuit Electronic Relay Module Delayed Power Off XY LJ02

13,95 €
Envio GRATUITO

Cycle Trigger Delay Timer Switch Circuit Electronic Relay Module Delayed Power Off XY LJ02

  • Marca: Unbranded
Vendido por:

Cycle Trigger Delay Timer Switch Circuit Electronic Relay Module Delayed Power Off XY LJ02

  • Marca: Unbranded
PVP: 16,95 €
Preço: 13,95 €
Poupa: 3,00 € (17%)
Vendido por:
13,95 €
Envio GRATUITO

Em stock

Aceitamos as seguintes formas de pagamento

Descrição

Feature:1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical.2. Support high and low level trigger, switch control, suitable for most occasions.3. Wide voltage power supply (6-30V) supports micro USB 5.0V power supply, which is very convenient to use.4. The switch has a key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn the circuit.5. Added sleep mode, after enabling, no operation within 5 minutes, automatically turn off the LCD backlight; any key to wake up.6. Different OP, CL, LOP parameters can be set. These parameters are independent of each other and saved separately; all set parameters are automatically saved after power-off.7. With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will always remember after power off.Specification:Conditon: 100% Brand NewItem Type: Loop Timing ModuleMaterial: PlasticColor: As Pictures ShownSize: Approx. 8.0 x 3.8 x 1.9cm/3.1 x 1.5 x 0.7inWorking Voltage: 6-30V support micro USB 5.0V power supplyTrigger Signal Source: High level trigger (3.0V-24V), low level trigger (0.0V-0.2V), switch control (passive switch)Output Capability: Control devices within 30V 5A DC or within 220V 5A ACQuiescent Current: 15mA Working Current: 50mAService Life: More than 100,000 timesWorking Temperature: -40-85 Timing Range: 0.01 seconds (minimum) - 9999 minutes (maximum) continuously adjustableHow to Choose the Timing Range:In the OP/CL parameter modification interface, short press the STOP button to select the timing range;XXXX has no decimal point, and the timing range is 1s - 9999sXXX.X Decimal point in the tenth place, timing range 0.1s - 999.9sXX.XX Decimal point is in the hundredth place, timing range 0.01s - 99.99sX.X.X.X full decimal point, timing range 1min - 9999minFor example, if you want to set the OP to 3.2 seconds, then move the decimal point to the ten, the LCD display 003.2Parameter Description: OP on time, CL off time, LOP cycle times (1-9999 times, "----" represents infinite cycles)1. Parameter Settinga) Enter the setting interface by long pressing SET button;b) First set the working mode, the working mode flashes reminder, set the working mode by short pressing the UP/DOWN key;c) Short press SET button to select the working mode and enter the system parameter setting;d) On the system parameter setting interface, short press SET button to switch the system parameter to be modified, short press/long press UP/DOWN button to modify;(Note: Short press SET in P-1-p-3, P-7 mode is not valid )e) On the OP/CL parameter modification interface, short press STOP to switch the timing unit (1s/0.1s/0.01s/1min)f) After all parameter settings are completed, long press the SET button to save the parameter settings and exit the setting interfaceFunction:Remote data upload and parameter setting function:The system supports UART data upload and parameter setting function (TTL level);Additional Function:a) Automatic sleep function: In the running interface, long press the STOP button to start or close the automatic sleep function (L-P select on to start the sleep function, off to turn off the sleep function);b) Relay function selection: In the running interface, by short pressing the STOP button, start or close the relay function,'on' satisfies the conduction condition, the relay normally conducts,'OFF' satisfies the conduction condition, the relay does not conduct;'OFF' In the state, the system flashes to show'OUT';c) Parameter view: On the running interface, short press SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;d) Display content switching: In P-5 P-6 mode, switch display content (run time/cycle times) by short pressing DOWN key;Operating Mode:P1: After the signal is triggered, the relay is turned on for the OP time and then turned off; within the OP time, the signal is triggered again invalidP2: After the signal is triggered, the relay turns on the OP time and then turns off; within the OP time, the signal is triggered again to retimeP3: After the signal is triggered, the relay is turned on for OP time and then disconnected; within OP time, the signal is triggered again to reset, the relay is turned off, and the timing is stoppedP4: Give the trigger signal, after the relay is turned off CL time, the relay is turned on OP time, after the timing is completed, the relay is turned off;P5: Give the trigger signal, after the relay turns on the OP time, the relay turns off the CL time, and then cycle the above actions, and the signal is given again in the cycle, the relay is turned off, and the timing is stopped; the number of cycles (LOP) can be set;P6: No trigger signal is required after power-on, the relay turns on the OP time, the relay turns off the CL time, and the above actions are cycled; the number of cycles (LOP) can be set;P7: signal hol
  • Identificação da Fruugo: 416670071-879145350
  • EAN: 7540131793486

Informações de segurança do produto

Consulte as informações de segurança do produto específicas para este produto descritas abaixo

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Etiquetas de segurança do produto

CE Mark
Avisos de segurança: Warning: Please read the product instructions carefully before use to ensure correct use.
Número de série: 7540131793486

Entrega e Devoluções

Enviado dentro de 2 dias

  • STANDARD: GRÁTIS - Entrega entre quarta 22 outubro 2025–quarta 29 outubro 2025 - GRÁTIS

Enviamos a partir de China.

Fazemos o nosso melhor para garantir que os produtos que encomendar lhe serão entregues na totalidade e conforme as suas especificações. No entanto, se receber uma encomenda incompleta ou itens diferentes dos que encomendou, ou existir qualquer outra razão pela qual não estiver satisfeito com a sua encomenda, poderá devolver a encomenda ou quaisquer produtos incluídos na mesma, e receber um reembolso total dos itens. Ver a política de devoluções na íntegra

Detalhes de conformidade do produto

Consulte as informações de conformidade específicas para este produto descritas abaixo.

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Fabricante:
As informações seguintes apresentam os dados de contacto do fabricante do produto em causa vendido na Fruugo.

  • Wuhan Pinsheng Technology Co., Ltd.
  • Wuhan Pinsheng Technology Co., Ltd.
  • No.A357,Shoulder-to-shoulder?Incubator,Building?4
  • Wuchang District
  • Wuhan
  • CN
  • 430000
  • pinsenkj@163.com
  • 18062524796
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

Pessoa responsável na UE:
As informações seguintes apresentam os dados de contacto da pessoa responsável na UE. A pessoa responsável é o operador económico designado, sedeado na UE, incumbido das obrigações de conformidade relativas ao produto em causa vendido na União Europeia.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795