999A 30V 60W/120W Multi-function Constant Current Digital Display Electronic Load Tester Discharge Capacity Tester Aging Module

69,00 €
+ 11,49 € Envio

999A 30V 60W/120W Multi-function Constant Current Digital Display Electronic Load Tester Discharge Capacity Tester Aging Module

  • Marca: Unbranded
Vendido por:

999A 30V 60W/120W Multi-function Constant Current Digital Display Electronic Load Tester Discharge Capacity Tester Aging Module

  • Marca: Unbranded

69,00 €

Economize 110,00 € (61%)

PVP

179,00 €
Em stock
+ 11,49 € Envio

Política de Devoluções de 14 Dias

Vendido por:

69,00 €

Economize 110,00 € (61%)

PVP

179,00 €
Em stock
+ 11,49 € Envio

Política de Devoluções de 14 Dias

Métodos de pagamento:

Descrição

999A 30V 60W/120W Multi-function Constant Current Digital Display Electronic Load Tester Discharge Capacity Tester Aging Module

999A 30V 60W/120W Multi-function Constant Current Digital Display Electronic Load Tester Discharge Capacity Tester Aging Module Product selling points: 1.Adopting high quality materials, long service life, high quality circuit, stable and efficient performance. 2.Reverse connection protection: with reverse connection protection, even if the wires are connected in reverse, it will not be damaged. 3. With fan control: Intelligent fan control (the fan can automatically and infinitely variable speed according to the temperature of the radiator). 4. Protection functions: overheating protection "otP", instantaneous over power protection "oPP", over voltage protection "ouP", reverse connection protection, abnormal power supply voltage protection. 5. Wide range of applications: can measure the actual capacity of the battery, test the actual power of the load and other purposes. 6. Increase the support for four-wire test in electronic load mode, with independent four-wire voltage indicator. Product parameters: Working power supply: DC12V regulated (11-13V) not less than 0.5A, the power supply is not appropriate will display Err6 Interface: 5.5 * 2.1mm round mouth inside the positive pole Operating mode: single mode constant current (CC) Discharge current: 0.10-9.99A step 0.1A or 0.01A Discharge current error: 0.7% plus or minus 0.01A Capacity test error does not exceed: 0.5A 2%, 2A 1.5%, 5A and above 1.2% Lower limit (termination) voltage setting range: 0.9-28.0V in steps of 1V or 0.1V Discharge voltage: 0.90-30.00V (subject to MOS internal resistance and other losses, the measured input 1V can support up to 6-7A current, 9.99A need to be measured when the voltage is greater than 1.3V) Voltage measurement error does not exceed: 0.8% ± 0.02V Power: 112W over power automatic current limitation (for example, for 110W, 11V can open 9.99A while in 20V can only open 5.5A) Power: 62W Automatic current limit for over power (e.g. for 60W, 9.99A at 6V and 3.00A at 20V) Battery test statistics limit: 999.9Ah or 9999Wh, reach the value to stop the test (to the first to the value of the stop condition) Product size: 110W: 122mm * 70mm * 77mm (fan protrudes from the board about 22mm) 60W: 106.5mm*70mm*57.5mm (fan protrudes from the board about 12mm) Positioning hole position: 60mm * 88mm hole diameter 3.2mm installed 5mm post (60W for copper post 110W for insulated nylon post) Operating instructions: I. Function mode setting (default factory electronic load mode): press and hold "ON/OFF" at the same time to energise the tester until the display of Fun* and then release the button, at this time to enter the function setting menu. Change the setting by rotating the knob, switch to the next step by pressing "ON/OFF", and set in the following order: 1. Mode setting "Fun1" is electronic load mode, "Fun2" is battery capacity test mode. 2. Buzzer switch setting "bEon" buzzer on, "bEoF" buzzer off. 3. Display brightness setting "Lt-1" "Lt-2" "Lt-3", three brightness levels can be selected. Finish this again press "ON/OFF" to save and exit the setting. Afterwards, the tester will restart and enter into normal working condition. Second, the electronic load mode: 1. Turn on the 12V power supply, make sure that it is in the stop state ("RUN" lamp does not light up, otherwise press the "ON/OFF" off) under the connection of the power supply under test to the power input port (P + P-), such as the use of four-wire connection, please at the same time will be If using four-wire connection method, please connect the voltage detection line to the (V+V-) socket at the same time. If the measured power supply voltage is higher than 1V, the voltage will be displayed automatically, and the "L-4" lamp will light up when it is recognised as 4-wire mode. Note: Do not touch the radiator with the screwdriver when wiring, and do not connect the negative pole anyway. 2. Set the current and lower limit voltage by knob, rotate the knob to set the value of the current setting position, press the knob to switch the setting digit, the number of the current setting position will be flashing, more than 3 seconds of non-operation will automatically exit the setup to return to the normal display of voltage and current. 3. Press "ON/OFF", the load starts to run, "RUN" lights up, the circuit applies the set discharge current to the input power supply to be measured, and at the same time displays the actual input voltage of the load on the upper line, when the voltage is lower than the set lower limit voltage, "RUN" lights up, the circuit applies the set discharge current to the input power supply to be measured, and at the same time displays the actual input voltage of the load on the upper line. When the voltage is lower than the set lower limit voltage, "RUN" lamp flashes and accompanied by a short buzzer alarm. 4. The current can be modified at any time during the
  • Identificação da Fruugo: 456466320-961849387
  • EAN: 7537532492711

Informações de segurança do produto

Consulte as informações de segurança do produto específicas para este produto descritas abaixo

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Etiquetas de segurança do produto

CE Mark
Avisos de segurança: WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Ingredientes: Octinoxate 3.3341%
Número da peça do fabricante: ZC300872
Número do modelo: ZC858112
Número de série: ZC003352
Número do lote: ZC001432

Entrega e Devoluções

Enviado dentro de 3 dias

  • EXPRESS: 11,49 € - Entregue por quinta 15 janeiro 2026 - Mais barato - Mais rápido

  • STANDARD: 11,49 € - Entrega entre segunda 26 janeiro 2026–quinta 05 fevereiro 2026

Enviamos a partir de China.

Fazemos o nosso melhor para garantir que os produtos que encomendar lhe serão entregues na totalidade e conforme as suas especificações. No entanto, se receber uma encomenda incompleta ou itens diferentes dos que encomendou, ou existir qualquer outra razão pela qual não estiver satisfeito com a sua encomenda, poderá devolver a encomenda ou quaisquer produtos incluídos na mesma, e receber um reembolso total dos itens. Ver a política de devoluções na íntegra

Detalhes de conformidade do produto

Consulte as informações de conformidade específicas para este produto descritas abaixo.

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Fabricante:
As informações seguintes apresentam os dados de contacto do fabricante do produto em causa vendido na Fruugo.

  • Ningbo Sida Yuandong Import & Export
  • Ningbo Sida Yuandong Import & Export Co., Ltd.
  • No. 360 Shengmo Road, Qiuai Town, Yinzhou District Ningbo
  • Ningbo
  • China
  • 315101
  • pyls55967@163.com
  • 17719951355
  • https://www.fruugo.co.uk/search?merchantId=15958

Pessoa responsável na UE:
As informações seguintes apresentam os dados de contacto da pessoa responsável na UE. A pessoa responsável é o operador económico designado, sedeado na UE, incumbido das obrigações de conformidade relativas ao produto em causa vendido na União Europeia.

  • EC REP SERVICES SL
  • EC REP SERVICES SL
  • Calle Gran Via 49, 7 DCH.
  • Madrid
  • Spain
  • 28013
  • ECREPSERVICE@HOTMAIL.COM
  • 34682797075