70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

34,06 €
+ 7,37 € Envio

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • Marca: Unbranded

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • Marca: Unbranded
Preço: 34,06 €
Vendido por:
34,06 €
+ 7,37 € Envio

Em stock

Aceitamos as seguintes formas de pagamento

Descrição

Item Type: Blood Oxygen Probe <br>Material: Plastic <br>Applicable for CSI models, others are not applicable <br>Specification: LED 660nm/905nm/940nm <br>Maximum Output Power: 15 mw <br>Suitable for Adults with a weight >40kg, clamped on the index finger or any finger. <br> <br>Spo2 Test Range: 70%~100% <br>Spo2 Test Accuracy: ±2% when 90%~100%, ±3% when 70%~89% <br>Pulse Rate Test Range: 30~245 bpm <br>Pulse Rate Test Accuracy: ±3 bpm <br>Main Structure: Consists of plug, cable and probe <br>Application: Used for pulse oximeters and multi-parameter monitors to continuously and non-invasively collect and transmit the pulse and oxygen saturation signals of patients (adults with a body weight >40kg); not suitable for weak perfusion and exercise conditions Monitoring, the probe is not suitable for long-term monitoring, it should be checked every 4 hours or measured with 2 fingers. <br> <br>Contraindications: Do not fix this product in a location where the patient has tissue damage; it is not suitable for patients and users who are allergic to PVC, TPU, TPE, ABS plastics. <br> <br>Warning: <br>A) Improper use will cause inaccurate measurement. <br>B) When the light is too strong, the measurement will be inaccurate. In some cases, a piece of opaque material should be used to shade the light around the sensor. <br>C) The blood oxygen saturation probe should be moved to a new location at least every 4 hours. Because local skin conditions will affect the ability of the skin to withstand the placement of the probe, it is necessary to change the position of the sensor frequently according to the conditions of some patients. If the integrity of the skin changes, the probe needs to be moved to another location. <br>D) Dye in the blood vessel will cause inaccurate measurement. <br>E) The performance of the probe is easily affected by activities, so it is not suitable for active patients. <br>F) Do not use straps to fix the probe or tie it to death, because venous pulsation will cause inaccurate saturation measurement. <br>G) Like other armarium, cables should be placed so as not to entangle or suffocate the patient. <br>H) Do not use during MRI scan. Because the conductor current will cause burns. Moreover, the blood oxygen saturation probe will affect the MRI image, and the MRI device will also affect the accuracy of the blood oxygen measurement. <br>I) Do not change or modify this product at will. Because this will affect its performance or accuracy. <br>J) Do not use radiation, steam or ethylene oxide for degassing. <br>K) Do not immerse the product in liquid for cleaning and degassing. <br>L) Mobile phones or mobile RF communication equipment will affect the operation of this sensor. <br> <br>How to Use: <br>1) Place your index finger on the sensor window of the pulse oximetry probe, and touch the stop button at the end of your finger. <br>2) If the nail is too long, it will affect the fingertip to touch the stop button. <br>3) Open the lower cover of the finger clamp of the sensor to apply even force to the entire length of the gasket. Check the location of the sensor. If the index finger is placed incorrectly or cannot be used, you can use other fingers or use other types of oxygen sensors. Do not use the pulse oximetry probe on children’s thumbs or toes, or on the entire hands and feet. <br>Note: When selecting the sensor placement site, priority should be given to the limb site without arterial catheter, blood pressure cuff and venous infusion tube. <br>4) When placing the sensor, route the cable along the back of the hand. <br>5) Connect the pulse oximetry probe to the oximeter and check whether the operating procedure complies with the steps described in the operating manual. <br>Note: If the sensor cannot accurately monitor the pulse beating, it means that its position is improper or its place
  • Marca: Unbranded
  • Categoria: Oxímetros de Pulso
  • Peso: 0.1
  • Comprimento: 5
  • Altura: 5
  • Largura: 5
  • Identificação da Fruugo: 379354635-818866684

Entrega e Devoluções

Enviado dentro de 24 horas

  • STANDARD: 7,37 € - Entrega entre quinta 02 outubro 2025–quinta 09 outubro 2025

Enviamos a partir de China.

Fazemos o nosso melhor para garantir que os produtos que encomendar lhe serão entregues na totalidade e conforme as suas especificações. No entanto, se receber uma encomenda incompleta ou itens diferentes dos que encomendou, ou existir qualquer outra razão pela qual não estiver satisfeito com a sua encomenda, poderá devolver a encomenda ou quaisquer produtos incluídos na mesma, e receber um reembolso total dos itens. Ver a política de devoluções na íntegra

Detalhes de conformidade do produto

Consulte as informações de conformidade específicas para este produto descritas abaixo.

As informações a seguir são fornecidas pelo revendedor independente que vende este produto.

Fabricante:
As informações seguintes apresentam os dados de contacto do fabricante do produto em causa vendido na Fruugo.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 1401-04 Yousuo Bldg 2000
  • Jiaxian Road Gangtou Community
  • Bantian Subdistrict
  • Shenzhen
  • China
  • 518500
  • szrhkj41@163.com
  • 15819859068

Pessoa responsável na UE:
As informações seguintes apresentam os dados de contacto da pessoa responsável na UE. A pessoa responsável é o operador económico designado, sedeado na UE, incumbido das obrigações de conformidade relativas ao produto em causa vendido na União Europeia.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736